Sunday, February 13, 2011

Ventilation Heat Recovery (MVHR) the Heart of every Passive House


Ventilation Heat Recovery (MVHR)
PAUL Comfort Ventilation is a leader in the field of mechanical ventilation heat recovery (MVHR). Established in 1994, PAUL has pioneered the development of highly efficient, very quiet, domestic heat recovery units, alongside applying the same standards to commercial sized units.
Combining their patented channel counter flow heater exchangers with the very latest in low energy dc silent fan technology means that PAUL units achieve the very highest standards. PAUL products have both SAP Appendix Q listing and Passive House Institute certification.

Advantages:
  • Real energy savings                
  • Lower heating bills
  • Constant fresh air
  • Low pollen levels
  • Reduced humidity
  • Quieter living
  • Cooling in summer
  • Constant odour & dust mite removal
  • No mildew or mould
  • In ground loop for fresh air intake

The Heat Exchanger
The heart of every PAUL Comfort Ventilation system is the heat exchanger. This is where the heat from the outgoing air is transferred to the incoming air. This works both ways so if the outside temperature is higher than inside the exchanger helps to maintain a constant pleasant internal climate.
The unique patented PAUL counter flow heat exchanger design has proven itself to be one of the most efficient on the market. Combined with a surface area of 60m² in the family house size units provides exceptional heat recovery of up to 99% (thermos 200 dc 97- 99% at 200m³ /h).



Designed to be Inaudible
The high quality balanced fans and attention to detail make PAUL units the quietest on the market. There is no point in building a low energy house if people don't want to live in it. Experience has shown that when constant, even low noise levels prove to be disturbing. Combine PAUL quality with the very best ducting design drawing on years of experience from Germany, the  PAUL suppliers are able to provide a service of the very highest standard.
Air Quality
Paul Comfort Ventilation uses high quality large surface area filters that ensure a clean air supply. The large surface area of the filters provides an extended service interval and reduces loss of flow. A properly tuned comfort ventilation system prevents CO2 build up with out the need to open windows. Removing the need to open windows has the added benefit of keeping the noise of contemporary life out side the home.
Product Range
PAUL Comfort Ventilation units can be fitted in suspended ceilings, horizontally in boxing over kitchen cupboards, vertically in a larder unit, or a utility room or garage. They can supply ventilation demands from 30 to 6000m³/h. The compact units utilise air source heat pump technology to provide both heat and hot water along side the ventilation requirement.

Saturday, February 12, 2011

High R-Value Windows Are Top Pick To Improve Home Energy Performance



Question #1: If I have a budget of $15,000 to spend on retrofitting a home to improve energy performance, what gives the biggest bang for the buck?
The energy performance gains of three different options were studied to find out which options gives the biggest bang for the buck:

OPTION 1 Increase efficiency: improve attic and under-floor insulation, thoroughly air-seal the enclosure, and upgrade lighting and appliances to ENERGY STAR-compliant models.





OPTION 2 Replace windows: replace all existing windows with R-5 windows. Two base case scenarios were examined, one with R-1 (single-pane) windows and the second with R-2 (double-pane) windows in the existing home.


OPTION 3 Install solar system: install a 2-kW photovoltaic array on the roof.
Result: R-5 windows are the most cost-effective energy-saving solution for residential home retrofit projects when replacing single-pane windows and are cost-competitive with other options even when replacing dual-pane windows.

According to Ann’s study, R-5-and-above windows represent a game-changing entry into the residential replacement window market and into the broader realm of energy efficiency retrofit options. While in the past, window replacement was not typically viewed as offering a good return on investment from an energy perspective (though often attractive for reasons of improved comfort), it should now be considered routinely for home energy retrofit projects.
Question #2: If I’m building a new home, which energy variables have the greatest influence on the overall energy performance of a new home?
Energy variables studied included building orientation, wall insulation, roof insulation, window area, window R-values, window solar heat gain coefficient (SHGC), and HVAC (heating, ventilation, and air conditioning) equipment efficiency.
Result: Window R-value often has the greatest influence on energy performance compared to other common energy variables. High R-value windows (R-5 or greater) provide excellent energy savings.
In all but one scenario modeled, window R-value (the inverse of U-value) had the greatest influence range of the variables studied. High R-value windows are likely to provide excellent performance benefits in many projects, particularly those with a high window-to-floor area ratio.